| - | {{ :shopping.png?400 |}} | + | The Neptune 4 is equipped with an inductive probe that triggers from the metal build plate and measures the distance from the probe to the plate which in turn is translated to a Z distance of the nozzle above the bed. Because of this operation without the plate or trying to use glass or garolite plates can result in nozzle crashes. |
| + | |||
| + | The probe is highly accurate with a precision in fractions of a micron. | ||
| + | |||
| + | It's located in the left rear of the print head and above the nozzle. A small red LED indicates its operation. | ||
| + | |||
| + | Note that the probe position is different, or offset, from the nozzle and so when it's probing it's the probe that's over the probed position not the nozzle. | ||