probe_calibration
Differences
This shows you the differences between two versions of the page.
| Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
| probe_calibration [2026/08/03 21:26] – dshoop | probe_calibration [2026/08/03 21:41] (current) – dshoop | ||
|---|---|---|---|
| Line 6: | Line 6: | ||
| {{: | {{: | ||
| - | == Please Note == | + | === Please Note === |
| Calibrating the z probe is NOT the same as setting the gcode z offset. | Calibrating the z probe is NOT the same as setting the gcode z offset. | ||
| Line 15: | Line 15: | ||
| Like many things Klipper, you'll need to use at least Fluidd to access the Klipper console. You can also use it to edit [[printer.cfg]] if you don't use ssh or other methods. | Like many things Klipper, you'll need to use at least Fluidd to access the Klipper console. You can also use it to edit [[printer.cfg]] if you don't use ssh or other methods. | ||
| - | ==== About Probe Calibrate ==== | + | ===== About Probe Calibrate |
| See https:// | See https:// | ||
| Line 27: | Line 27: | ||
| - | ==== Example ==== | + | ===== Example ===== |
| + | |||
| + | In the Klipper [[console]] first home the tool and then enter the Probe Calibrate routine. | ||
| < | < | ||
| Line 37: | Line 39: | ||
| // Finish with ACCEPT or ABORT command. | // Finish with ACCEPT or ABORT command. | ||
| // Z position: ?????? --> 6.520 <-- ?????? | // Z position: ?????? --> 6.520 <-- ?????? | ||
| + | </ | ||
| + | |||
| + | Use the TESTZ command as described in the documentation to move the nozzle up or down (using suitable - or + values, ) until the nozzle firmly holds onto the paper. (A PostIt Note, sticky side up, is recommended, | ||
| + | |||
| + | < | ||
| $ TESTZ Z=-6.420 | $ TESTZ Z=-6.420 | ||
| // Z position: ?????? --> 0.100 <-- 6.520 | // Z position: ?????? --> 0.100 <-- 6.520 | ||
| Line 63: | Line 70: | ||
| #*# | #*# | ||
| </ | </ | ||
| - | If you see a value like '' | + | If you see a value like '' |
| < | < | ||
| [probe] | [probe] | ||
/app/data/attic/probe_calibration.1785806795.txt.gz · Last modified: by dshoop