orca_calibrations
Differences
This shows you the differences between two versions of the page.
| Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
| orca_calibrations [2026/01/13 19:28] – dshoop | orca_calibrations [2026/10/20 14:32] (current) – dshoop | ||
|---|---|---|---|
| Line 3: | Line 3: | ||
| Proper calibration of the Filament Profile is essential for good prints. Orca slicer has several built in calibration tests to assist in determining the specific profile values. | Proper calibration of the Filament Profile is essential for good prints. Orca slicer has several built in calibration tests to assist in determining the specific profile values. | ||
| + | |||
| + | Before filament calibration make sure your filament is dry. Filament is shipped from the factory wet, so unless you specifically dry it in a heated dryer it's expected to be wet. Desiccant will not dry your filament, alone. While PLA is the least hydrophilic of the filaments you're likely to use, and it doesn' | ||
| Specifically you should calibrate for each of your filaments: | Specifically you should calibrate for each of your filaments: | ||
| Line 10: | Line 12: | ||
| * extrusion temperatures | * extrusion temperatures | ||
| * gcode z offset | * gcode z offset | ||
| + | |||
| + | Most critical of these are gcode z offset, pressure advance and flow ratio. The others are more forgiving. | ||
| A great guide that would be hard to do better in terms of explanations is at https:// | A great guide that would be hard to do better in terms of explanations is at https:// | ||
| Line 15: | Line 19: | ||
| For calibrating flow ratio, I prefer the following calibration test over the Orca test as it’s less subjectively focused and more functionality focused, uses way less filament and prints quicker: https:// | For calibrating flow ratio, I prefer the following calibration test over the Orca test as it’s less subjectively focused and more functionality focused, uses way less filament and prints quicker: https:// | ||
| - | Additionally you may want to perform some experiments to address overhang and bridging settings. | + | Additionally you may want to perform some experiments to address overhang and bridging settings. Both the slicer speeds differentiated over the overhang % can be calibrated or adjusted. |
| + | |||
| + | The Temperature Tower, as part of evaluating & calibrating extruder temperature, | ||
| + | |||
| + | Klipper has built in test towers to vary any parameter or variable over a range based on Z height and can be used to build all sorts of tests to calibrate quickly. | ||
| + | |||
| + | === Order of operations === | ||
| + | |||
| + | Each calibration does affect the other, Extruder temperature affects max volumetric flow rate and flow ratio. Max volumetric flow rate affects pressure advance. | ||
| + | |||
| + | As each test's calibrated parameters can influence the other tests the recommended order is: | ||
| + | |||
| + | - extruder temperature | ||
| + | - MVFR | ||
| + | - pressure advance | ||
| + | - flow ration | ||
| + | - retraction distance | ||
| + | |||
| + | And after this you may want to repeat the temperature tower test for further tuning bridges, overhangs and fine temperature adjustment. | ||
| ==== Additional Resources ==== | ==== Additional Resources ==== | ||
| + | |||
| + | === Factorial Designs: Filament Calibration Masterclass – 95% do it wrong! === | ||
| + | https:// | ||
| === Uncle Jesse: 3 Easy Ways to Calibrate Your Filament === | === Uncle Jesse: 3 Easy Ways to Calibrate Your Filament === | ||
/app/data/attic/orca_calibrations.1768350537.txt.gz · Last modified: by dshoop
