-(...work in progress...)+Generally nozzles are changed when wornClogged nozzle can normally be heater to a higher temp and flushedWhen the flow ratio needs adjusted further downwards is an indicator the nozzle is wearingIt also could be changed after repeated printing with highly abrasive materials such as metal filled, glow in the dark, glass, ceramic and excessive amounts of white filament (lots of titanium.) A worn nozzle can stillbe printed with if you recalibrate flow ratio and adjust line widths 